Specializing in the sales, service and installation of petroleum equipment |
| Valves Bypass |
||||||||||
![]() MR174-0100AV |
MORRISON 174 BYPASS VALVE — •Not a pressure regulating device. •Used in situations where pressure control —such as bypassing a pump to reduce pressure at the outlet— is necessary. •Available in pressure settings from 20 to 75psi. Valve settings are adjustable plus or minus 5 to 10psi from the factory set point. •Brass body construction. Includes stainless steel spring and Teflon® packing. |
MODEL MR174-0100AV MR174-1300AV MR174-1400AV MR174-1500AV MR174-1600AV MR174-1750AV MR174-2200AV MR174-2300AV MR174-2400AV MR174-2500AV MR174-2600AV MR174-2750AV |
DESCRIPTION |
Inquiries? Call us 8am-5pm Pacific time, or email us. |
||||||
![]() MR174AL-3300AV |
MORRISON 174AL BYPASS VALVE — •Not a pressure regulating device. •3" valve used in situations where pressure control —such as bypassing a pump to reduce pressure at the outlet— is necessary. •Available in pressure settings from 20 to 75psi. Valve settings are adjustable plus or minus 5 to 10psi from the factory set point. •Aluminum body construction. Includes stainless steel spring and Teflon® packing. |
MODEL MR174AL-3200AV MR174AL-3300AV MR174AL-3400AV MR174AL-3500AV MR174AL-3600AV MR174AL-3750AV Parts MR174AL-03032S MR174-01092S MR174AL-S02092S MR174AL-37592S |
DESCRIPTION |
|||||||
| Expansion relief |
||||||||||
![]() MR77-0200AV |
MORRISON 77 EXPANSION RELIEF VALVE — •Utilized on aboveground storage tank piping to relieve excess pressure due to outside temperature rise. •.25" valve is especially suited to existing pipelines and bypassing a valve that doesn't have expansion relief. •Approx. 40psi relief setting. •Copper tubing is not supplied. |
MODEL MR77-0200AV Parts MR77-02062F MR77-02072F |
DESCRIPTION |
|||||||
![]() MR78DI-0100AV |
MORRISON 76DI/78DI EXP RELIEF VALVE — •Used on aboveground storage tank piping to relieve excess pressure. •.5" valve allows product to return to the storage tank. •Model 76DI: Precise pressure settings (25 or 50psi). Primarily used with leak detection systems. •Model 78DI: Approximate pressure settings of 25psi, 40psi (standard) and 100 psi. •Ductile iron construction |
MODEL Precise MR76DI-0100AV MR76DI-0200AV Approximate MR78DI-0100AV MR78DI-0200AV MR78DI-0300AV Parts MR78-01032S MR78-02052S MR78-03062S |
DESCRIPTION |
|||||||
![]() OCV108-2 |
OCV MODEL 108 PRESSURE VALVE — •Acts as a backpressure or pressure sustaining valve, maintaining constant upstream pressure regardless of any fluctuation in downstream demand. Typically mainline size, the maximum velocity through the valve should not exceed 25 ft/sec. •When used in a bypass line, this model acts as a relief valve to protect the system against potentially damaging surges. Size is determined by the amount of pressure that is required to lower the inlet pressure. A general guideline is to use 60% of the rated pump flow. Capable of intermittent flows of up to 45 ft/sec. •Quick opening with controlled closing. •Size range: 1.25" to 24". These valves are typically 50-60% of the mainline size. •Flow range maximums: 115gpm @ 25 ft/sec or 210gpm @ 45 ft/sec (1.25") low end, 31,250gpm @ 25 ft/sec or 56,000gpm @ 45 ft/sec (24") high end. |
MODEL OCV108-2 OCV108-3 OCV108-4 OCV108-34 OCV108-8 |
DESCRIPTION |
DOCS Features Install/ops 108-2 108-3 |
||||||
![]() OCV118-3 |
OCV MODEL 118/108SA SURGE VALVE — •Designed to be installed in a bypass line to assist in preventing damaging surges that occur in pumping systems when the pump suddenly stops. •Differs from conventional relief valves in that while standard valves only open when a high pressure wave hits, the surge protection valve senses the precursor of the high pressure wave (pump power failure or low pressure wave) and opens the valve in anticipation of the high pressure wave that follows. •Model 108SA is a hydraulic model requiring no electrical. •Model 118 is electro-hydraulic. It features an electrical power connection to the pumping system for opening upon loss of poweror on a pressure switch 'low pressure' signal. The valve closes after an adjustable pre-determined time on power failure or low pressure opening. Pilot- operated, hydraulic high pressure relief opening. •Size range: 1.25" to 24". |
MODEL Hydraulic OCV108SA Electro-Hyd OCV118-2 OCV118-3 OCV118-4 |
DESCRIPTION |
DOCS Features Install/Ops 118-3 |
||||||
| Pressure differential |
||||||||||
![]() OCV110 |
OCV MODEL 110 DIFFERENTIAL VALVE — •Controls the pressure difference between two points. Pilot-operated, modulating type valve. •Differential is adjustable over a complete range of control springs. •Installed on the discharge side of a pump. Valve senses high pressure on the pump discharge side (the valve inlet) and low pressure at the pump suction. The valve modulates to hold differential pressure constant and thus assure that the pump is at its optimum point on the curve. •Size range: 1.25" to 24". •Flow range maximums: 115gpm @ 25 ft/sec (1.25") low end, 31,300gpm @ 25 ft/sec (24") high end. |
MODEL OCV110 OCV110-1 OCV110-2 OCV110-12 |
DESCRIPTION |
DOCS Features Install/ops |
||||||
Pump control |
||||||||||
![]() OCV125-27 |
OPW MODEL 125 PUMP CONTROL VALVE — •Electronically interfaced with a pump motor, this valve is designed to effectively eliminate surges associated with the starting and stopping of a pump motor. It opens and closes at an adjustable speed. •Multiple configurations and combinations. •Includes built-in reverse flow check feature. •Automatically shuts off pump motor upon loss of pump discharge pressure. •Size range: 1.25" to 24". •Flow range maximums: 85gpm @ 25 ft/sec or 127gpm @ 30 ft/sec (1.25") low end, 25,000gpm @ 20 ft/sec or 37,500gpm @ 30 ft/sec (24") high end. |
MODEL OCV125-1B OCV125-2 OCV125-7 OCV125-8 OCV125-13 OCV125-13E OCV125-14 OCV125-15 OCV125-27 OCV125-134 OCV125-137 OCV125-157 OCV125-1347 |
DESCRIPTION |
DOCS Features Install/ops 125-7 125-27 |